“Narrow linewidth” sounds like a single specification. It is not. Our own catalogue carries four lasers that genuinely earn the label, and the narrowest is more than twenty thousand times narrower than the widest. Both ends are the right answer for someone — but rarely for the same person.
This guide explains how to compare linewidths quoted in different units, which of two very different regimes your application needs, and the three separate specifications that tend to get lumped together under one heading.
One Linewidth, Three Units
Linewidth is the width of the laser's emission spectrum. The difficulty is that different communities quote it in different units:
- Nanometres or picometres — common on datasheets, especially for diode lasers.
- Megahertz or gigahertz — the laser physicist's unit, used for single-frequency sources.
- Wavenumbers (cm⁻¹) — the spectroscopist's unit, and the one Raman spectra are plotted in.
Converting between them depends on wavelength. For a linewidth Δλ at wavelength λ:
Δν (Hz) = c · Δλ / λ² and Δν̃ (cm⁻¹) = Δλ / λ²
A linewidth that looks identical in nanometres is therefore not identical everywhere: 0.06 nm is wider in frequency at 633 nm than at 980 nm. Applied to our four narrow-linewidth lasers:
| Laser | Datasheet linewidth | In frequency | In wavenumbers | Coherence length (approx.) |
|---|---|---|---|---|
| DMCN-633 | < 0.06 nm | ~45 GHz | ~1.5 cm⁻¹ | ~7 mm |
| DMCN-785 | < 0.06 nm | ~29 GHz | ~1.0 cm⁻¹ | ~1 cm |
| DLCZ-980 | < 0.06 nm | ~19 GHz | ~0.6 cm⁻¹ | ~1.6 cm |
| SLCP-532 | < 1 MHz | < 0.001 GHz | ~0.00003 cm⁻¹ | ~300 m |
The first three sit together. The fourth is in a different world. That gap is the whole story of this post.
Regime One: Spectroscopy-Grade (~0.06 nm)
The DMCN and DLCZ-980 lasers are wavelength-stabilized diodes. A wavelength-selective element forces the diode to emit in a narrow band instead of across the broad spectrum a free-running multimode diode produces — which is commonly a nanometre or more wide.
For Raman spectroscopy, that difference is decisive. Every measured Raman peak is the true peak convolved with the laser line, so a laser a nanometre wide at 785 nm — roughly 16 cm⁻¹ — smears the spectrum badly. At about 1 cm⁻¹, the DMCN-785's line is narrower than the Raman bands of most liquids and solids, which are typically several wavenumbers wide or more, and comparable to or finer than the resolution of typical spectrometers. The laser stops being the limiting factor. Where higher resolution is needed, the < 0.03 nm option halves it again.
This is why going narrower than ~0.06 nm usually buys a Raman user nothing: once the laser line is narrower than the bands and the spectrometer's resolution, further narrowing does not show up in the data. The full case for 785 nm Raman is in 785 nm lasers for Raman spectroscopy.
What spectroscopy-grade linewidth does not give you is long coherence. Around a centimetre is plenty for spectroscopy, but far too short for most holography or interferometry with any real path difference.
Regime Two: Single-Frequency (< 1 MHz)
The SLCP-532 is a single-frequency DPSS laser, oscillating on one longitudinal mode, with a linewidth below 1 MHz. Spectroscopists rarely need this. Interferometry and holography do — because what they depend on is coherence length.
Coherence length is roughly how far apart two parts of the beam can travel and still interfere cleanly. It scales inversely with linewidth; to order of magnitude it is c / Δν. (Definitions differ by a factor of two or three depending on line shape, but the scaling is what matters.) A 1 MHz line gives a coherence length of the order of a hundred metres or more; a 29 GHz line gives about a centimetre.
The consequences follow directly:
- Holography needs coherence length longer than the optical path difference across the recording geometry — often metres for large-format work. Only the single-frequency class qualifies. See 532 nm vs. 561 nm for why the green line is the usual choice.
- Interferometers with unequal arms — displacement measurement, Michelson and Mach–Zehnder setups, surface profiling over depth — need coherence longer than the arm imbalance. A spectroscopy-grade diode only works if the arms are matched to within millimetres.
- Brillouin and other ultra-high-resolution spectroscopy probe features far finer than a wavenumber, and need a correspondingly narrow line.
Three Specifications, Not One
Buyers often ask for “a narrow, stable wavelength” as though it were one property. It is three, and our datasheets list them separately for good reason.
| Specification | What it describes | DMCN-633 / DMCN-785 | DLCZ-980 | SLCP-532 |
|---|---|---|---|---|
| Linewidth | How wide the line is at any moment | < 0.06 nm (< 0.03 nm option) | < 0.06 nm | < 1 MHz |
| Frequency shift | How far the line wanders over time and temperature | < 20 pm over ±2 °C and 2 hours | Not specified | Not specified |
| Centre wavelength | Where the line sits, unit to unit | ± 0.5 nm | ± 5 nm | ± 1 nm |
Each one matters to a different part of the measurement.
Linewidth sets resolution or coherence, as above.
Frequency shift sets repeatability. Raman shifts are calculated relative to the laser line, so if the line drifts during an acquisition, every peak position drifts with it. At 785 nm, 20 pm is about 0.3 cm⁻¹ — small enough to leave peak positions intact. For comparison, a free-running diode's wavelength typically moves on the order of 0.3 nm for every degree of temperature change, and can jump abruptly between modes.
Centre wavelength tolerance sets compatibility. A narrow line is no use if it sits on the wrong side of your laser-line or edge filter. The DLCZ-980 illustrates the distinction neatly: its line is narrow (< 0.06 nm), but any individual unit may sit anywhere within ± 5 nm of 980 nm. If your optics are designed around an exact wavelength, ask for the measured value — every laser we ship comes with its measured performance data — before you buy the filters.
What Narrow Linewidth Costs
Spectral purity is not free, and the trade-offs are visible in the specifications.
- Power. The DMCN lasers deliver 1–50 mW and the DLCZ-980 1–30 mW, against up to 1000 mW for our standard 633 nm diodes and 2500 mW at 785 nm. Raman rarely needs more — but check before assuming.
- Modulation. The DMCN lasers are CW only, and the DLCZ-980 datasheet specifies no modulation input. Changing a diode's drive current shifts its wavelength, which is exactly what stabilization exists to prevent. Plan on an external shutter or modulator for gating; see TTL vs. analog modulation.
- Environment. All three stabilized diodes specify 20–30 °C operation, narrower than the 10–35 °C of our general-purpose lines. Holding a wavelength demands tighter thermal conditions.
- Polarization. The DMCN-785 specifies > 10:1 as standard, with > 50:1 as an option — worth checking if your spectrometer or filters are polarization-sensitive.
The SLCP-532 escapes most of these. As a DPSS laser it reaches 1000 mW, carries TTL and analog modulation, holds TEM₀₀ at M² < 1.2, and operates from 10 to 35 °C. The cost there is wavelength choice: single-frequency output is offered at 532 nm.
How to Decide
- Raman or other spectroscopy? Spectroscopy-grade is the right class. Choose DMCN-785 for most samples, DMCN-633 where you want stronger scattering and fluorescence is not a problem. Consider the < 0.03 nm option only if your spectrometer resolves better than about a wavenumber.
- Holography or unequal-arm interferometry? You need coherence length, which means single-frequency: SLCP-532.
- Matched-arm interferometry or sensing at 980 nm? The DLCZ-980 offers a narrow line in the near-infrared; confirm the measured centre wavelength against your optics.
- Need to pulse the laser? Rule out the stabilized diodes, or budget for an external modulator.
- Quantitative work over long acquisitions? Check the frequency-shift specification, not just the linewidth.
Aimpico Narrow-Linewidth Lasers
Our narrow-linewidth range covers both regimes. For spectroscopy: the DMCN-785 and DMCN-633, each < 0.06 nm (< 0.03 nm optional) with < 20 pm frequency shift and ± 0.5 nm centre wavelength, and the DLCZ-980 at < 0.06 nm in the near-infrared. For coherence: the SLCP-532, single-frequency at < 1 MHz with up to 1000 mW and TEM₀₀ beam quality.
Tell us whether you need resolution or coherence, your spectrometer or interferometer configuration, and the filters you are using, and we will point you at the right line — including when a standard laser will do.
Not sure which kind of narrow linewidth you need?